Medical Equipment, Patient Monitor (8.4-inch)

Product Details
Customization: Available
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Still deciding? Get samples of US$ 400/Piece
Request Sample
Manufacturer/Factory, Trading Company, Group Corporation
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9000, GMP, ISO 13485
OEM/ODM Availability
Yes
  • Medical Equipment, Patient Monitor (8.4-inch)
  • Medical Equipment, Patient Monitor (8.4-inch)
  • Medical Equipment, Patient Monitor (8.4-inch)
  • Medical Equipment, Patient Monitor (8.4-inch)
  • Medical Equipment, Patient Monitor (8.4-inch)
  • Medical Equipment, Patient Monitor (8.4-inch)
Find Similar Products

Basic Info.

Model NO.
8.4-inch
Certification
CE, ISO13485
Group
Adult and Children
Display
8.4 LCD Screen
Transport Package
Carton
Specification
CE, FDA
Trademark
JYK
Origin
Guangdong, China
Production Capacity
500unit/Month

Product Description

Medical equipment, 8.4 inch patient monitor
 
 
Features:

NIBP:
Method: Oscillometry
Modes: Manual/Auto/Comtinuous
Auto measure time:Adjustable
Measurement rang:10-270mmHg
ECG:
Lead mode:3-lead or 5-lead
Lead selection:I;II;III;avR;avL;avF;V
Heart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
ECG waveform: 2 channals
Accuracy: ± 1 bpm or ±1%
S-T segment detection Measurement rang :-0.2mv~2.0mv
Alarm:Yes,audible and visual alarm,alarm events review
High resolution 12.1"color TFT display
Lightweight,compact and portable
ECG,APO2,NIBP,RESP,2-TEMP,PR
Optional:2-IBP,ETCO2,And thermal printer
Bulit-in rechargeable lithium battery
ECG waveforms of 7-leads display on the same screen
72-hours graphic and tabular trends of all parameters
72 alarm events of all parameters recall
32 seconds full-disclosure waveform review
500 NIBP measurement date can be storage and recall
Date and waveforms color be adjustable
Arrhythmia analysis and S-T segment analysis
Suitable for adult,pediatric and neonatal patient
SPO2
Measurement range:0-100%
Accyracy:70-100%, ±2% 0-69%,upspecified
Pulse rate
Range:20-254bpm
Accuracy: ±3bpm
Respiration
Method:RA-LL impedance
Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnca alarmYes
Temperature
Range:0-50
Apnca: 0.1
Channal:Dual-Channal
EtCO2(optional)
Units: mmHg; kPa;  %
Method:  Non-dispersive infrared; autocalibrating
N2O Compensation: Manual; On/Off, user selectable
Range:  0 to 114 mmHg; 0 to 15%
Flow, Sample Rate:  Mini/Sidestream; 50 ml/min
Accuracy:  ±2 mmHg or 5% of reading
Printer (optional)
Type: Thermal line printer
Paper Speed: 12.5, 25 or 50 mm/sec
channal number dual-channal
discreen display  12.1 inches
measurement range  10-270mmHg
Medical equipment, 8.4 inch patient monitor
 
 
Features:

NIBP:
Method: Oscillometry
Modes: Manual/Auto/Comtinuous
Auto measure time:Adjustable
Measurement rang:10-270mmHg
ECG:
Lead mode:3-lead or 5-lead
Lead selection:I;II;III;avR;avL;avF;V
Heart rate range:Adult:15-300bpm;Pediatric/Neonatal:15-300bpm
ECG waveform: 2 channals
Accuracy: ± 1 bpm or ±1%
S-T segment detection Measurement rang :-0.2mv~2.0mv
Alarm:Yes,audible and visual alarm,alarm events review
High resolution 12.1"color TFT display
Lightweight,compact and portable
ECG,APO2,NIBP,RESP,2-TEMP,PR
Optional:2-IBP,ETCO2,And thermal printer
Bulit-in rechargeable lithium battery
ECG waveforms of 7-leads display on the same screen
72-hours graphic and tabular trends of all parameters
72 alarm events of all parameters recall
32 seconds full-disclosure waveform review
500 NIBP measurement date can be storage and recall
Date and waveforms color be adjustable
Arrhythmia analysis and S-T segment analysis
Suitable for adult,pediatric and neonatal patient
SPO2
Measurement range:0-100%
Accyracy:70-100%, ±2% 0-69%,upspecified
Pulse rate
Range:20-254bpm
Accuracy: ±3bpm
Respiration
Method:RA-LL impedance
Range:Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnca alarmYes
Temperature
Range:0-50
Apnca: 0.1
Channal:Dual-Channal
EtCO2(optional)
Units: mmHg; kPa;  %
Method:  Non-dispersive infrared; autocalibrating
N2O Compensation: Manual; On/Off, user selectable
Range:  0 to 114 mmHg; 0 to 15%
Flow, Sample Rate:  Mini/Sidestream; 50 ml/min
Accuracy:  ±2 mmHg or 5% of reading
Printer (optional)
Type: Thermal line printer
Paper Speed: 12.5, 25 or 50 mm/sec
channal number dual-channal
discreen display  12.1 inches
measurement range  10-270mmHg
Medical Equipment, Patient Monitor (8.4-inch)
Medical Equipment, Patient Monitor (8.4-inch)
Medical Equipment, Patient Monitor (8.4-inch)
Medical Equipment, Patient Monitor (8.4-inch)
Medical Equipment, Patient Monitor (8.4-inch)
Medical Equipment, Patient Monitor (8.4-inch)
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier